Champion Power Equipment
Champion 3600 Watt LPG Dual Fuel Inverter
UK flag Model: CPG4000DHY-DF

Champion 3600 Watt LPG Dual Fuel Inverter

3 Year Limited Warranty
Starting Watts: 4500
Rated Watts: 3500
Max Watts: 3600
Start Type: Recoil,Electric
3 Year Warranty
3 Year Warranty
This product carries a 3 Year Warranty.
Dual Fuel
Dual Fuel
Run this generator on either propane or petrol.
EU Stage V Compliant
EU Stage V Compliant
This generator is EU Stage V Compliant.
E10 Petrol Compliant
E10 Petrol Compliant
This generator is E10 Petrol Compliant.
Cold Start Technology
Cold Start Technology
These generators have been designed to start even in extremely cold temperatures. (You can watch our Siberia Cold Test Chamber videos on our website!)
Electric Start
Electric Start
These generators can be started by a push button or electric key start.
Overload Protection
Overload Protection
To help prevent damage to the engine, Overload Protection will automatically switch the generator off when it detects that the power usage exceeds the rated wattage.
Automatic Voltage Regulator
Automatic Voltage Regulator
AVR technology provides a steady motor speed alongside excellent emissions. This creates an environmentally friendly generator with reduced noise.
Volt Guard
Volt Guard
To prevent damage to the engine, the Volt Guard continuously monitors the voltage output of the generator and will shut it down should any irregularities appear.
Champion 3600 Watt LPG Dual Fuel Inverter Champion 3600 Watt LPG Dual Fuel Inverter Champion 3600 Watt LPG Dual Fuel Inverter Champion 3600 Watt LPG Dual Fuel Inverter Champion 3600 Watt LPG Dual Fuel Inverter Champion 3600 Watt LPG Dual Fuel Inverter Champion 3600 Watt LPG Dual Fuel Inverter
3 Year Warranty
3 Year Warranty
This product carries a 3 Year Warranty.
Dual Fuel
Dual Fuel
Run this generator on either propane or petrol.
EU Stage V Compliant
EU Stage V Compliant
This generator is EU Stage V Compliant.
E10 Petrol Compliant
E10 Petrol Compliant
This generator is E10 Petrol Compliant.
Cold Start Technology
Cold Start Technology
These generators have been designed to start even in extremely cold temperatures. (You can watch our Siberia Cold Test Chamber videos on our website!)
Electric Start
Electric Start
These generators can be started by a push button or electric key start.
Overload Protection
Overload Protection
To help prevent damage to the engine, Overload Protection will automatically switch the generator off when it detects that the power usage exceeds the rated wattage.
Automatic Voltage Regulator
Automatic Voltage Regulator
AVR technology provides a steady motor speed alongside excellent emissions. This creates an environmentally friendly generator with reduced noise.
Volt Guard
Volt Guard
To prevent damage to the engine, the Volt Guard continuously monitors the voltage output of the generator and will shut it down should any irregularities appear.

Quieter, Smaller & Lighter than traditional generators - and coming soon with Dual Fuel capability!

By integrating digital components used in more advanced inverters – known as Quiet Technology –and utilizing a more efficient mechanical design, Champion were able to cut the generator’s noise level and reduce its overall footprint and weight significantly.

Champion's CPG4000DHY-DF Digital Hybrid features Quiet Technology, Extended Run Time, Economy Mode, and Clean Power, this Digital Hybrid inverter has the advanced power you need.

Champion’s reliable 224cc Champion engine produces 3500 running watts, and runs for 14 hours at 25% load with the 11 litre fuel tank or 18 hours on LPG with a 20 litre Gas Bottle. With a 0.6 litre oil capacity (recommended 10W-30) and a low oil shut-off sensor, this inverter operates at 64 dBA from 7m (23ft).

Confidently connect your sensitive electronics since our hybrid produces only Clean Power (less than 3% THD). The foldaway easy-grip handle and included wheel kit with never-flat tires make it a cinch to move your power where you need it.

Buy this CE and EU5 certified generator with confidence – Champions legendary Customer Service Team will support your purchase with a 3-year limited warranty and FREE lifetime technical support.

The benefits of LPG:

  • The biggest attraction of LPG is the lower running costs (bottled gas is about 30% - 50% cheaper to run currently than petrol, the larger the cylinder the cheaper the gas becomes). As fuel becomes more expensive this becomes an even more attractive offer.
  • You have greater flexibility with regards to extending the running time, just use a bigger cylinder if you need a longer running time; you are no longer limited by the internal fuel tank.
  • Cleaner emissions allows for use in situations where petrol is not appropriate such as around food or on those sites that do not allow petrol for fire risk precautions.
  • There are also no petrol storage problems, eg. Smells.
  • Minimal risk of fuel spillage, as the fuel is not “loose”/fluid, also there is less chance of the fuel source being stolen.
  • Lower maintenance costs due to the cleaner running; petrol decays over time and can block the carburettor or hinder its operation.
  • LPG does not have this problem as the LPG is sealed there is no chance of degradation. This leads to extended life of the spark plug and generator components.
  • A lot easier to refuel just connect up a new bottle. With more and more councils and campsites banning the use of petrol and diesel we feel that the demand of LPG Generators will only increase in the future.

Please note that the majority of the competitions Dual Fuel models in the UK tend to be “retrofits” which invalidate the Manufacturer’s Warranty! Whilst Champion lead the way with their dual fuel patented technology & their machines are Factory fitted & therefore the 3 years Manufacturer’s Warranty is fully supported.

Features:

  • 3500 Running Watts
  • Clean Power - Low THD (3% or less)
  • Extended run time - Up to 18 hours run time at 25% load
  • Quick touch panel - all controls on one panel
  • Economy mode - save fuel and extend engine life
  • True sine wave inverter technology

All newly manufactured products are EU Stage V Compliant.

Starting Watts 4500 Petrol / 4500 LPG
Max Watts 3600 Petrol / 3600 LPG
Rated Watts 3500 Petrol / 3150 LPG
AC Load 1 x 240v 13 Amp
1 x 240v 16 Amp
Phase Single
Power Factor 1
RPM Automatic (Based on load)
Engine 224cc
Fuel Capacity 11 Litres
Oil Capacity 0.6 Litres
Start Type Recoil,Electric
Low Oil Shutoff Automatic
Noise Level @ 7m 64 dBA
Dimensions L*W*H
(Fully Assembled)
59.8 x 60.1 x 55 cm
Weight 39.7kg (88 lbs)
Operation at 25% (Eco Mode) 14.5 / 18 (LPG) hours
Overload Protection
AVR
Cold Start
Volt Guard
Parallel Connectivity
Electric Start
Wheels Never Flat
Certification EU Stage V,RED,E10 Petrol Compliant,UKCA
Warranty 3 Year Limited Warranty

Starting vs Max vs Running Watts

Most motor-driven products that you will connect to your generator need extra watts when they start, this is known as starting watts.

The Starting Watts listed on your generator is the wattage the generator can output for an average of 6 seconds (Inverter) or 10 minutes (Open Frame Type).

Once this period is over, and if the wattage has not reduced the Overload Protection will activate and the generator will trip using the following methods circuit breaker (frame type) and flashing overload light (Inverter), if this happens the power (wattage) needs to reduced or disconnected immediately and the generator needs to be reset by stopping the generator and turning everything to the ‘OFF’ position and leaving for minimum 2 minutes (Inverter Only).

The Maximum Watts listed on your generator is the MAX watts output the generator can run at – however it is not recommended to run your generator at the  maximum watts for periods more than average 5 minutes (Inverter) and 60 minutes (Open Frame Type). Once this period is over, and if the wattage has not reduced the Overload Protection will activate and the generator will trip using the following methods circuit breaker (frame type) and flashing overload light (Inverter), if this happens the power (wattage) needs to reduced or disconnected immediately and the generator needs to be reset by stopping the generator and turning everything to the ‘OFF’ position and leaving for minimum 2 minutes. While working in the max zone on an Inverter you will have solid red overload light this is normal.